Blog: Cabling Chronicles | Page 4 | www.flukenetworks.com

Cabling Chronicles

2017-02-15

Back when Wolfenstein 3D was all the rage, we set up an exhibit at a BICSI conference where we tried to make a Cat 5 link fail by inducing noise onto it. We tried all kinds of no-no’s, such as placing the cable next to a fluorescent ballast, a large electric motor, and even the coil of a running car’s engine, yet the link provided virtually error-free 100BASE-TX performance. At that point, it didn’t seem like there would be much benefit for screened cable for the vast majority of installations.

2017-02-08

 

The 2017 BICSI Winter Conference wrapped up last week in Tampa where thousands of ICT professional from around the world had a chance to gain valuable industry knowledge and check out the latest products from nearly 180 vendors in the exhibit hall – including our new DSX-8000 CableAnalyzer.

2017-02-02

On January 23, we announced the DSX-8000 CableAnalyzer™, the first true Category 8 tester.  You may be wondering what is required for a “true” Category 8 certification tester and why we launched it now.

2017-01-25

A wire map test may seem like the most basic test for copper network cabling and therefore one of the least important, but it is actually one of the most critical. And while the pair colors of blue, orange, green and brown might help you pass wire map testing, the test itself really doesn’t care about color at all.

Let’s take a closer look.

2017-01-18

 

So you came across some Category 6 cable available online for practically half what you've been paying for that brand name. It claims TIA-568-C compliance, includes the UL listing mark and even has a ETL verification legend printed right on the cable. Before you get too excited, you might want to make sure that cable isn't made with copper clad aluminum (CCA).

2017-01-04

 

All over the news and social media, 2016 has gotten a pretty bum rap.

With everything from shootings, terrorist attacks and the weirdest presidential election in history, to exploding cell phones, scary clown threats and numerous celebrity deaths, 2016 has been denoted as the worst year ever.

2016-12-30

The only way to get correct values when performing Tier 2 testing of duplex fiber links with an OTDR is via bidirectional testing that averages the measurements taken from both ends of the link.

Bidirectional testing used to involve testing the fiber from one end, walking the OTDR to the other end to test again and then averaging the two values to get the results—and it had to be done for each link.

2016-12-22

'Twas the night before Christmas when all through the LAN, 
the channels were tested except for the SAN.
MPOs easy with MultiFiber™ Pro,
gave me hope I'd be done before fallen snow.
With SmartLoop letting me to test from one end,
I knew that I'd soon start my weekend.

2016-12-14

 

It's that time of year again when we take a look at what we predict to be next year's biggest trends in testing.

Obviously the Internet of Things (IoT) will continue to be a major driver in all things network cabling--from the LAN where we will see more devices than ever residing on copper twisted-pair network cabling, to the data center where demand for high speed fiber links continues to expand as companies are faced with the need to access, transmit and store more data than ever before.